Leadtools.Dicom Requires Medical product license | Send comments on this topic. | Back to Introduction - All Topics | Help Version 15.10.31
SendCMoveResponse Method
See Also 
Leadtools.Dicom Namespace > DicomNet Class : SendCMoveResponse Method




presentationID
The Presentation Context ID. The ID provides information about both the class type of the data and the Transfer Syntax to use when transferring the data.
messageID
The Message ID. Each message sent by a member of a connection should have a unique ID. Since a member of a connection may send several messages, this ID allows that member to identify when a specific request has been completed.
affectedClass
The class affected by the request. This will be a SOP Class or a Meta SOP Class.
status
The status of the original request.
remaining
The number of remaining instances to search.
completed
The number of instances searched.
failed
The number of instances that failed the search.
warning
The number of instances in which warnings occurred.
dataSet
A DicomDataSet object that contains the Data Set used for sending additional information about a non-successful C-MOVE sub-operation. This may be a null reference (Nothing in Visual Basic).
Sends a C-MOVE-RSP message to a peer member of a connection.

Syntax

Visual Basic (Declaration) 
Public Sub SendCMoveResponse( _
   ByVal presentationID As Byte, _
   ByVal messageID As Integer, _
   ByVal affectedClass As String, _
   ByVal status As DicomCommandStatusType, _
   ByVal remaining As Integer, _
   ByVal completed As Integer, _
   ByVal failed As Integer, _
   ByVal warning As Integer, _
   ByVal dataSet As DicomDataSet _
) 
Visual Basic (Usage)Copy Code
Dim instance As DicomNet
Dim presentationID As Byte
Dim messageID As Integer
Dim affectedClass As String
Dim status As DicomCommandStatusType
Dim remaining As Integer
Dim completed As Integer
Dim failed As Integer
Dim warning As Integer
Dim dataSet As DicomDataSet
 
instance.SendCMoveResponse(presentationID, messageID, affectedClass, status, remaining, completed, failed, warning, dataSet)
C# 
public void SendCMoveResponse( 
   byte presentationID,
   int messageID,
   string affectedClass,
   DicomCommandStatusType status,
   int remaining,
   int completed,
   int failed,
   int warning,
   DicomDataSet dataSet
)
Managed Extensions for C++ 
public: void SendCMoveResponse( 
   byte presentationID,
   int messageID,
   string* affectedClass,
   DicomCommandStatusType status,
   int remaining,
   int completed,
   int failed,
   int warning,
   DicomDataSet* dataSet
) 
C++/CLI 
public:
void SendCMoveResponse( 
   byte presentationID,
   int messageID,
   String^ affectedClass,
   DicomCommandStatusType status,
   int remaining,
   int completed,
   int failed,
   int warning,
   DicomDataSet^ dataSet
) 

Parameters

presentationID
The Presentation Context ID. The ID provides information about both the class type of the data and the Transfer Syntax to use when transferring the data.
messageID
The Message ID. Each message sent by a member of a connection should have a unique ID. Since a member of a connection may send several messages, this ID allows that member to identify when a specific request has been completed.
affectedClass
The class affected by the request. This will be a SOP Class or a Meta SOP Class.
status
The status of the original request.
remaining
The number of remaining instances to search.
completed
The number of instances searched.
failed
The number of instances that failed the search.
warning
The number of instances in which warnings occurred.
dataSet
A DicomDataSet object that contains the Data Set used for sending additional information about a non-successful C-MOVE sub-operation. This may be a null reference (Nothing in Visual Basic).

Example

For an example, refer to SendCMoveRequest.

Remarks

SendCMoveResponse is called by the SCP in response to a SendCMoveRequest call placed by an SCU. This generates a call to OnReceiveCMoveResponse on the SCU.

Requirements

Target Platforms: Microsoft .NET Framework 2.0, Windows 98, Windows NT 4.0, Windows Millennium Edition, Windows 2000, Windows XP Home Edition, Windows XP Professional, Windows Server 2003 family

See Also

Leadtools.Dicom requires a Medical toolkit license and unlock key. For more information, refer to: Raster Pro/Document/Medical Features