Leadtools.Dicom Requires Medical product license | Send comments on this topic. | Back to Introduction - All Topics | Help Version 16.5.9.25
OnReceiveAssociateAccept Method
See Also 
Leadtools.Dicom Namespace > DicomNet Class : OnReceiveAssociateAccept Method



association
A DicomAssociate object.
association
A DicomAssociate object.
Notifies a connection that an Associate Accept message was received.

Syntax

Visual Basic (Declaration) 
Protected Overridable Sub OnReceiveAssociateAccept( _
   ByVal association As DicomAssociate _
) 
Visual Basic (Usage)Copy Code
Dim instance As DicomNet
Dim association As DicomAssociate
 
instance.OnReceiveAssociateAccept(association)
C# 
protected virtual void OnReceiveAssociateAccept( 
   DicomAssociate association
)
C++/CLI 
protected:
virtual void OnReceiveAssociateAccept( 
   DicomAssociate^ association
) 

Parameters

association
A DicomAssociate object.

Example

For an example, refer to SendAssociateRequest.

Remarks

A call to this method is generated on an SCU when an SCP calls SendAssociateAccept.

To customize this method, you must derive a class from DicomNet and override this method.

A DICOM Association must be established between an SCU and an SCP before any DICOM messages or data can be transmitted between them. For more information on creating a DICOM Association, refer to Creating a DICOM Associate Connection.

When a DICOM Associate Connection is no longer needed, the connection should be closed. For more information, refer to Closing a DICOM Associate Connection.

Requirements

Target Platforms: Microsoft .NET Framework 3.0, Windows XP, Windows Server 2003 family, Windows Server 2008 family

See Also

Leadtools.Dicom requires a Medical toolkit server license and unlock key. For more information, refer to: Imaging Pro/Document/Medical Features