OnReceiveCStoreResponse Method
See Also 
Leadtools.Dicom.Scu Namespace > StoreScu Class : OnReceiveCStoreResponse Method




presentationID
The Presentation Context ID. The ID provides information about both the class type of the data and the Transfer Syntax to use when transferring the data.
messageID
The Message ID. Each message sent by a member of a connection should have a unique ID. Since a member of a connection may send several messages, this ID allows that member to identify when a specific request has been completed.
affectedClass
The class affected by the request. This will be a SOP Class or a Meta SOP Class.
instance
The instance of the class. A server may, for example, have three instances of the Nuclear Medicine Class. This value identifies the data with a specific instance.
status
The status of the original request.
presentationID
The Presentation Context ID. The ID provides information about both the class type of the data and the Transfer Syntax to use when transferring the data.
messageID
The Message ID. Each message sent by a member of a connection should have a unique ID. Since a member of a connection may send several messages, this ID allows that member to identify when a specific request has been completed.
affectedClass
The class affected by the request. This will be a SOP Class or a Meta SOP Class.
instance
The instance of the class. A server may, for example, have three instances of the Nuclear Medicine Class. This value identifies the data with a specific instance.
status
The status of the original request.
Notifies a connection that a C-STORE-RSP command was received.

Syntax

Visual Basic (Declaration) 
Overrides Protected Sub OnReceiveCStoreResponse( _
   ByVal presentationID As Byte, _
   ByVal messageID As Integer, _
   ByVal affectedClass As String, _
   ByVal instance As String, _
   ByVal status As DicomCommandStatusType _
) 
Visual Basic (Usage)Copy Code
Dim instance As StoreScu
Dim presentationID As Byte
Dim messageID As Integer
Dim affectedClass As String
Dim instance As String
Dim status As DicomCommandStatusType
 
instance.OnReceiveCStoreResponse(presentationID, messageID, affectedClass, instance, status)
C# 
protected override void OnReceiveCStoreResponse( 
   byte presentationID,
   int messageID,
   string affectedClass,
   string instance,
   DicomCommandStatusType status
)
Managed Extensions for C++ 
protected: void OnReceiveCStoreResponse( 
   byte presentationID,
   int messageID,
   string* affectedClass,
   string* instance,
   DicomCommandStatusType status
) override 
C++/CLI 
protected:
void OnReceiveCStoreResponse( 
   byte presentationID,
   int messageID,
   String^ affectedClass,
   String^ instance,
   DicomCommandStatusType status
) override 

Parameters

presentationID
The Presentation Context ID. The ID provides information about both the class type of the data and the Transfer Syntax to use when transferring the data.
messageID
The Message ID. Each message sent by a member of a connection should have a unique ID. Since a member of a connection may send several messages, this ID allows that member to identify when a specific request has been completed.
affectedClass
The class affected by the request. This will be a SOP Class or a Meta SOP Class.
instance
The instance of the class. A server may, for example, have three instances of the Nuclear Medicine Class. This value identifies the data with a specific instance.
status
The status of the original request.

Remarks

A call to this method is generated on an SCU when SendCStoreResponse is called by an SCP. To customize this method, you must derive a class from DicomNet and override this method. When an SCU requests a Move (C-MOVE-REQ), the SCP may have to call SendCStoreRequest to request one or more C-STORE-REQ sub-operations to complete the storage. The series of calls and information transfer in a C-MOVE-REQ is complicated. For more information, refer to Moving Composite Data.