Available in LEADTOOLS Imaging Pro, Vector, Document, and Medical Imaging toolkits. |
LTwain::SetImageUnit
#include "ltwrappr.h"
L_INT LTwain::SetImageUnit (nUnit)
L_INT nUnit; |
/* image unit */ |
Sets the image unit value used to transfer images from the current TWAIN source.
Parameter |
Description |
nUnit |
Specifies the unit value to set. For more information on possible values, refer to http://www.twain.org/ and click on TWAIN Specification (Version 1.9). |
Returns
SUCCESS |
The function was successful. |
< 1 |
An error occurred. Refer to Return Codes. |
Comments
This function internally sets the image unit capability ICAP_UNITS. For more information on this capability, refer to http://www.twain.org/ and click on TWAIN Specification (Version 1.9).
To obtain the current image unit value, call the LTwain::GetImageUnit function.
Required DLLs and Libraries
LTTWN For a listing of the exact DLLs and Libraries needed, based on the toolkit version, refer to Files To Be Included With Your Application. |
See Also
Example
L_INT LTwain__SetImageUnitExample(LTwain * plTwain) { L_INT nRet = SUCCESS; L_INT nUnit; nRet = plTwain->GetImageUnit (&nUnit); if (nRet == SUCCESS) { if (nUnit == TWUN_INCHES) { nRet = plTwain->SetImageUnit(TWUN_INCHES); if(nRet != SUCCESS) return nRet; } } else return nRet; L_INT nBPP; nRet = plTwain->GetImageBitsPerPixel (&nBPP); if (nRet == SUCCESS) { if (nBPP == 24) plTwain->SetImageBitsPerPixel (24); } else return nRet; return SUCCESS; }