LEADTOOLS WIA (Leadtools.Wia assembly) Send comments on this topic. | Back to Introduction - All Topics | Help Version 17.0.3.30
SetPropertySystemTime Method
See Also 
Leadtools.Wia Namespace > WiaSession Class : SetPropertySystemTime Method



item
Handle to the item which represents the item having the property. You can retrieve this parameter by either calling the WiaSession.GetRootItem method to get the device’s root item itself or by enumerating the child items of the device through a call to Leadtools.Wia.WiaSession.EnumChildItems method.
propertyIdName

This string should contain the equivalent property Id string for the WIA property ID. Use the see GetPropertyIdString method to get this string for the property ID.

If you passed null for this parameter then the WIA toolkit will use the property ID passed through the third parameter propertyId; otherwise this parameters will be used whether or not you passed valid property ID through the propertyId parameter

propertyId

The property ID for the value being sought, for list of available property IDs see WiaPropertyId.

This parameter is required only if the second parameter "propertyIdName"is null; otherwise you can pass 0 for this parameter.

value

The WIA date value to set.

item
Handle to the item which represents the item having the property. You can retrieve this parameter by either calling the WiaSession.GetRootItem method to get the device’s root item itself or by enumerating the child items of the device through a call to Leadtools.Wia.WiaSession.EnumChildItems method.
propertyIdName

This string should contain the equivalent property Id string for the WIA property ID. Use the see GetPropertyIdString method to get this string for the property ID.

If you passed null for this parameter then the WIA toolkit will use the property ID passed through the third parameter propertyId; otherwise this parameters will be used whether or not you passed valid property ID through the propertyId parameter

propertyId

The property ID for the value being sought, for list of available property IDs see WiaPropertyId.

This parameter is required only if the second parameter "propertyIdName"is null; otherwise you can pass 0 for this parameter.

value

The WIA date value to set.

Sets the date and time of the specified item as a form of System.DateTime structure for WIA property type WiaVariableTypes.UI2 or WiaVariableTypes.Vector.

Syntax

Visual Basic (Declaration) 
Public Sub SetPropertySystemTime( _
   ByVal item As Object, _
   ByVal propertyIdName As String, _
   ByVal propertyId As WiaPropertyId, _
   ByVal value As Date _
) 
Visual Basic (Usage)Copy Code
Dim instance As WiaSession
Dim item As Object
Dim propertyIdName As String
Dim propertyId As WiaPropertyId
Dim value As Date
 
instance.SetPropertySystemTime(item, propertyIdName, propertyId, value)
C# 
public void SetPropertySystemTime( 
   object item,
   string propertyIdName,
   WiaPropertyId propertyId,
   DateTime value
)
C++/CLI 
public:
void SetPropertySystemTime( 
   Object^ item,
   String^ propertyIdName,
   WiaPropertyId propertyId,
   DateTime value
) 

Parameters

item
Handle to the item which represents the item having the property. You can retrieve this parameter by either calling the WiaSession.GetRootItem method to get the device’s root item itself or by enumerating the child items of the device through a call to Leadtools.Wia.WiaSession.EnumChildItems method.
propertyIdName

This string should contain the equivalent property Id string for the WIA property ID. Use the see GetPropertyIdString method to get this string for the property ID.

If you passed null for this parameter then the WIA toolkit will use the property ID passed through the third parameter propertyId; otherwise this parameters will be used whether or not you passed valid property ID through the propertyId parameter

propertyId

The property ID for the value being sought, for list of available property IDs see WiaPropertyId.

This parameter is required only if the second parameter "propertyIdName"is null; otherwise you can pass 0 for this parameter.

value

The WIA date value to set.

Example

Remarks

Call this function to set the passed items date and time through the System.DateTime structure for any WIA property of type /// WiaVariableTypes.UI2 or WiaVariableTypes.Vector (for instance, WiaPropertyId.DeviceTimeWiaPropertyId.ItemTime ).

For more information, refer to Managing WIA Sources.

Requirements

Target Platforms: Microsoft .NET Framework 2.0, Windows 2000, Windows XP, Windows Server 2003 family, Windows Server 2008 family, Windows Vista, Windows 7

See Also