LEADTOOLS Medical (Leadtools.Dicom.Scp assembly) Send comments on this topic. | Back to Introduction - All Topics | Help Version 17.0.3.29
CMoveCommandOperationCanceledException Constructor
See Also 
Leadtools.Dicom.Scp.Command.Exceptions Namespace > CMoveCommandOperationCanceledException Class : CMoveCommandOperationCanceledException Constructor



failedSopDataSet
The Leadtools.Dicom.DicomDataSet which contains the SOP Instance UID for the failed to move instances.
remaining
The number of remaining C-STORE sub-operations
completed
The number of C-STORE sub-operations invoked by this C-MOVE operation which have completed successfully.
failure
The number of C-STORE sub-operations invoked by this C-MOVE operation which have failed.
warning
The number of C-STORE sub-operation invoked by this C-MOVE operation which generated Warning responses.
Initializes a new instance of the CMoveCommandOperationCanceledException class.

Syntax

Visual Basic (Declaration) 
Public Function New( _
   ByVal failedSopDataSet As DicomDataSet, _
   ByVal remaining As Integer, _
   ByVal completed As Integer, _
   ByVal failure As Integer, _
   ByVal warning As Integer _
)
Visual Basic (Usage)Copy Code
Dim failedSopDataSet As DicomDataSet
Dim remaining As Integer
Dim completed As Integer
Dim failure As Integer
Dim warning As Integer
 
Dim instance As New CMoveCommandOperationCanceledException(failedSopDataSet, remaining, completed, failure, warning)
C# 
public CMoveCommandOperationCanceledException( 
   DicomDataSet failedSopDataSet,
   int remaining,
   int completed,
   int failure,
   int warning
)
C++/CLI 
public:
CMoveCommandOperationCanceledException( 
   DicomDataSet^ failedSopDataSet,
   int remaining,
   int completed,
   int failure,
   int warning
)

Parameters

failedSopDataSet
The Leadtools.Dicom.DicomDataSet which contains the SOP Instance UID for the failed to move instances.
remaining
The number of remaining C-STORE sub-operations
completed
The number of C-STORE sub-operations invoked by this C-MOVE operation which have completed successfully.
failure
The number of C-STORE sub-operations invoked by this C-MOVE operation which have failed.
warning
The number of C-STORE sub-operation invoked by this C-MOVE operation which generated Warning responses.

Requirements

Target Platforms: Microsoft .NET Framework 2.0, Windows 2000, Windows XP, Windows Server 2003 family, Windows Server 2008 family, Windows Vista, Windows 7

See Also

Leadtools.Dicom.Scp requires a Medical toolkit license and unlock key. For more information, refer to: Raster Pro/Document/Medical Features