LEADTOOLS Medical (Leadtools.Dicom.Scu assembly)
LEAD Technologies, Inc

Get<TResult> Method






The type of the result.
The peer connection to send the N-SET-REQ to.
The abstract syntax. Valid values for the AbstractSyntax are Modality Performed Retrieve Class and General Purpose Performed Procedure Step.
The SOP Instance of the class. A server may, for example, have three instances of the Nuclear Modality Performed Retrieve Class. This value identifies the data with a specific instance.
The attributes to get. The attributes must be specified using the Data Element Tags.
Sends an N-GET-REQ to the SCP.
Syntax
'Declaration
 
Public Function Get(Of TResult)( _
   ByVal Scp As DicomScp, _
   ByVal AbstractSyntax As String, _
   ByVal SOPInstanceUID As String, _
   ByVal Attributes As List(Of Long) _
) As TResult
'Usage
 
Dim instance As PerformedProcedureStepScu
Dim Scp As DicomScp
Dim AbstractSyntax As String
Dim SOPInstanceUID As String
Dim Attributes As List(Of Long)
Dim value As TResult
 
value = instance.Get(Of TResult)(Scp, AbstractSyntax, SOPInstanceUID, Attributes)
 function Leadtools.Dicom.Scu.PerformedProcedureStepScu.Get( 
   Scp ,
   AbstractSyntax ,
   SOPInstanceUID ,
   Attributes 
)
public:
TResult^ Getgeneric<typename TResult>
( 
   DicomScp^ Scp,
   String^ AbstractSyntax,
   String^ SOPInstanceUID,
   List<int64>^ Attributes
) 

Parameters

Scp
The peer connection to send the N-SET-REQ to.
AbstractSyntax
The abstract syntax. Valid values for the AbstractSyntax are Modality Performed Retrieve Class and General Purpose Performed Procedure Step.
SOPInstanceUID
The SOP Instance of the class. A server may, for example, have three instances of the Nuclear Modality Performed Retrieve Class. This value identifies the data with a specific instance.
Attributes
The attributes to get. The attributes must be specified using the Data Element Tags.

Type Parameters

TResult
The type of the result.

Return Value

The requested data return from the N-SET-REQ. TResult needs to have the correct attributes in order to be update with information from the returned dataset.
Requirements

Target Platforms: Windows 7, Windows Vista SP1 or later, Windows XP SP3, Windows Server 2008 (Server Core not supported), Windows Server 2008 R2 (Server Core supported with SP1 or later), Windows Server 2003 SP2

See Also

Reference

PerformedProcedureStepScu Class
PerformedProcedureStepScu Members

 

 


Products | Support | Contact Us | Copyright Notices

© 2006-2012 All Rights Reserved. LEAD Technologies, Inc.

Leadtools.Dicom.Scu requires a Medical toolkit license and unlock key. For more information, refer to: LEADTOOLS Toolkit Features