LEADTOOLS Medical (Leadtools.Dicom assembly)

DeleteWindow(Int32,DicomSetImageFlags) Method

Show in webframe







A zero-based index that identifies the frame number in the dataset. If the dataset does not support Multi-frames, this parameter is ignored.
determines how the VOI LUT is deleted
Deletes all the elements that describe "window center" and "window width".
Syntax
public void DeleteWindow( 
   int frameIndex,
   DicomSetImageFlags flags
)
'Declaration
 
Public Overloads Sub DeleteWindow( _
   ByVal frameIndex As Integer, _
   ByVal flags As DicomSetImageFlags _
) 
'Usage
 
Dim instance As DicomDataSet
Dim frameIndex As Integer
Dim flags As DicomSetImageFlags
 
instance.DeleteWindow(frameIndex, flags)
public void DeleteWindow( 
   int frameIndex,
   DicomSetImageFlags flags
)

            
public void deleteWindow(int frameIndex, int dicomSetImageFlags)
 function Leadtools.Dicom.DicomDataSet.DeleteWindow(Int32,DicomSetImageFlags)( 
   frameIndex ,
   flags 
)
public:
void DeleteWindow( 
   int frameIndex,
   DicomSetImageFlags flags
) 

Parameters

frameIndex
A zero-based index that identifies the frame number in the dataset. If the dataset does not support Multi-frames, this parameter is ignored.
flags
determines how the VOI LUT is deleted
Remarks

This method will delete the following elements:

Window Center (0028,1050)

Window Width (0028,1051)

Window Center and Width Explanation (0028,1055)


If the DICOM dataset has a Multi-frame Functional Groups module, the Window information will be found in the Frame VOI LUT Sequence. The Frame VOI LUT Sequencewill be under an item in either:
If the Frame VOI LUT Sequence is found under the Per-frame Functional Groups Sequence, parameter uFrameIndex must be set to the correct frame number so that the proper Frame VOI LUT Sequence is removed.

If the Frame VOI LUT Sequence is found under the Shared Functional Groups Sequence, parameter uFrameIndex is ignored. However, the DicomSetImageFlags.MfgOverwriteShared flag must be included to remove the Frame VOI LUT Sequence.
The specific elements deleted are shown below:

(0028,9132) Frame VOI LUT Sequence Child Elements
Tag Name
(0028,1050) Window Center
(0028,1051) Window Width
(0028,1055) Window Center & Width Explanation


Valid flags are DicomSetImageFlags.None and DicomSetImageFlags.MfgOverwriteShared. All other flags are ignored. For a detailed discussion on Multi-frame Functional Groups see the topic Multi-frame Functional Groups.
Example
For an example, refer to SetWindow(Int32,DicomWindowAttributes).
Requirements

Target Platforms

See Also

Reference

DicomDataSet Class
DicomDataSet Members
Overload List
GetWindowCount Method
VoiLutCount Property
GetWindow(Int32) Method
SetWindow(Int32,DicomWindowAttributes) Method
GetVoiLut Method
SetVoiLut Method
GetVoiLutData Method
DeleteVoiLut Method

 

 


Products | Support | Contact Us | Copyright Notices
© 2006-2014 All Rights Reserved. LEAD Technologies, Inc.

Leadtools.Dicom requires a Medical toolkit server license and unlock key. For more information, refer to: Imaging Pro/Document/Medical Features