Leadtools.Dicom Namespace > DicomNet Class : SetIsclMaxCommunicationBlockLength Method |
public void SetIsclMaxCommunicationBlockLength( int maxCommunicationBlockLength )
'Declaration Public Sub SetIsclMaxCommunicationBlockLength( _ ByVal maxCommunicationBlockLength As Integer _ )
'Usage Dim instance As DicomNet Dim maxCommunicationBlockLength As Integer instance.SetIsclMaxCommunicationBlockLength(maxCommunicationBlockLength)
public void SetIsclMaxCommunicationBlockLength( int maxCommunicationBlockLength )
function Leadtools.Dicom.DicomNet.SetIsclMaxCommunicationBlockLength( maxCommunicationBlockLength )
public: void SetIsclMaxCommunicationBlockLength( int maxCommunicationBlockLength )
Please note that the size of the ISCL packets is 32 bytes larger than the communication block length, because of the header.
During mutual authentication, the client and server will agree to use the smaller communication block size of the two.
Failure of the method usually occurs if maxCommunicationBlockLength is too small for the maximum standard packet size (168 bytes).