DeleteFilmBox Method
See Also 
Leadtools.Dicom Namespace > DicomPrintScu Class : DeleteFilmBox Method




Requests the Print SCP to delete the current Basic Film Box SOP Instance.

Syntax

Visual Basic (Declaration) 
Public Sub DeleteFilmBox() 
Visual Basic (Usage)Copy Code
Dim instance As DicomPrintScu
 
instance.DeleteFilmBox()
C# 
public void DeleteFilmBox()
Managed Extensions for C++ 
public: void DeleteFilmBox(); 
C++/CLI 
public:
void DeleteFilmBox(); 

Example

For an example, refer to Associate.

Remarks

Two of the exceptions that can be thrown by this method are:
Exception TypeCondition
DicomExceptionCode.PrintSCUFailureStatus The response of the Print SCP specifies a Failure status code.
DicomExceptionCode.PrintSCUClassNotSupported Neither the Basic Grayscale Print Management Meta SOP Class nor the Basic Color Print Management Meta SOP Class is supported on the Association.

There must be a Film Box currently created before using this method.

The method will not return until it receives the response of the Print SCP, or an error occurs. The method GetLastOperationStatus can be used to obtain the status code specified in the response of the Print SCP. If the method DeleteFilmBox is successful, the Film Box was deleted successfully, with either a Success or Warning status code in the response of the Print SCP.

Notice that deleting the Film Box will cause all the referenced Image Boxes and Annotation Boxes to be deleted also.

Requirements

Target Platforms: Microsoft .NET Framework 2.0, Windows 98, Windows NT 4.0, Windows Millennium Edition, Windows 2000, Windows XP Home Edition, Windows XP Professional, Windows Server 2003 family

See Also