LEADTOOLS Medical (Leadtools.Dicom assembly) Send comments on this topic. | Back to Introduction - All Topics | Help Version 17.0.3.29
SendCStoreResponse Method
See Also 
Leadtools.Dicom Namespace > DicomNet Class : SendCStoreResponse Method



presentationID
The Presentation Context ID. The ID provides information about both the class type of the data and the Transfer Syntax to use when transferring the data.
messageID
The Message ID. Each message sent by a member of a connection should have a unique ID. Since a member of a connection may send several messages, this ID allows that member to identify when a specific request has been completed.
affectedClass
The class affected by the request. This will be a SOP Class or a Meta SOP Class.
instance
The instance of the class. A server may, for example, have three instances of the Nuclear Medicine Class. This value identifies the data with a specific instance.
status
The status of the original request.
presentationID
The Presentation Context ID. The ID provides information about both the class type of the data and the Transfer Syntax to use when transferring the data.
messageID
The Message ID. Each message sent by a member of a connection should have a unique ID. Since a member of a connection may send several messages, this ID allows that member to identify when a specific request has been completed.
affectedClass
The class affected by the request. This will be a SOP Class or a Meta SOP Class.
instance
The instance of the class. A server may, for example, have three instances of the Nuclear Medicine Class. This value identifies the data with a specific instance.
status
The status of the original request.
Sends a C-STORE-RSP message to a peer member of a connection.

Syntax

Visual Basic (Declaration) 
Public Sub SendCStoreResponse( _
   ByVal presentationID As Byte, _
   ByVal messageID As Integer, _
   ByVal affectedClass As String, _
   ByVal instance As String, _
   ByVal status As DicomCommandStatusType _
) 
Visual Basic (Usage)Copy Code
Dim instance As DicomNet
Dim presentationID As Byte
Dim messageID As Integer
Dim affectedClass As String
Dim instance As String
Dim status As DicomCommandStatusType
 
instance.SendCStoreResponse(presentationID, messageID, affectedClass, instance, status)
C# 
public void SendCStoreResponse( 
   byte presentationID,
   int messageID,
   string affectedClass,
   string instance,
   DicomCommandStatusType status
)
C++/CLI 
public:
void SendCStoreResponse( 
   byte presentationID,
   int messageID,
   String^ affectedClass,
   String^ instance,
   DicomCommandStatusType status
) 

Parameters

presentationID
The Presentation Context ID. The ID provides information about both the class type of the data and the Transfer Syntax to use when transferring the data.
messageID
The Message ID. Each message sent by a member of a connection should have a unique ID. Since a member of a connection may send several messages, this ID allows that member to identify when a specific request has been completed.
affectedClass
The class affected by the request. This will be a SOP Class or a Meta SOP Class.
instance
The instance of the class. A server may, for example, have three instances of the Nuclear Medicine Class. This value identifies the data with a specific instance.
status
The status of the original request.

Example

For an example, refer to DicomNet.SendCStoreRequest.

Remarks

Leadtools.Dicom.DicomNet.SendCStoreResponse is sent by the SCP in response to a DicomNet.SendCStoreRequest call placed by an SCU. This generates a call to Leadtools.Dicom.DicomNet.OnReceiveCStoreResponse on the SCU.

Requirements

Target Platforms: Silverlight 3.0, Windows XP, Windows Server 2003 family, Windows Server 2008 family, Windows Vista, Windows 7, MAC OS/X (Intel Only)

See Also

Leadtools.Dicom requires a Medical toolkit server license and unlock key. For more information, refer to: Imaging Pro/Document/Medical Features