Available in LEADTOOLS Medical Imaging toolkits. |
L_DicomSetMaxMessageLengthISCL
#include "ltdic.h"
L_LTDIC_API L_UINT32 L_DicomSetMaxMessageLengthISCL(hNet, nMsgLength)
HDICOMNET hNet; |
/* handle to an existing DICOM network */ |
L_UINT32 nMsgLength; |
/* maximum message length */ |
Sets the maximum message length that can be processed (sent and received) by the current entity. This function is available in the PACS Imaging toolkits.
Parameter |
Description |
hNet |
Handle to an existing DICOM Network. This is the handle returned from the L_DicomCreateNet function. |
nMsgLength |
The maximum message length to set. |
Returns
DICOM_SUCCESS |
Success. The maximum message length was set using the nMsgLength parameter. |
DICOM_ERROR_PARAMETER |
An error occurred. This usually occurs if the nMsgLength was smaller than 136. (136 bytes is the maximum size of data in mutual authentication request packet.). Refer to Return Codes. |
Required DLLs and Libraries
LTDIC For a listing of the exact DLLs and Libraries needed, based on the toolkit version, refer to Files To Be Included With Your Application |
Win32, x64
See Also
Example
L_INT DicomSetMaxMessageLengthISCLExample(L_VOID) { L_INT nRet; HDICOMNET hDicomNet; hDicomNet = L_DicomCreateNet (TEXT(""), DICOM_SECURE_ISCL); nRet = L_DicomSetMaxMessageLengthISCL(hDicomNet, 1048576); // size of the message accepted is at most 1 MB � or 1048576 bytes return nRet; }