Available in LEADTOOLS Medical Imaging toolkits. |
L_DispContainerSetCellScaleMode
#include "l_bitmap.h"
L_LTIVW_API L_INT EXT_FUNCTION L_DispContainerSetCellScaleMode(hCellWnd, nSubCellIndex,, uScaleMode,uFlags)
HWND hCellWnd; |
/* handle to the cell window */ |
L_INT nSubCellIndex; |
/* index into the image list attached to the cell */ |
L_UINT uScaleMode; |
/* flag */ |
L_UINT uFlags; |
/* reserved for future use */ |
Sets the current scale mode for the specified cell or sub-cell.
Parameter |
Description |
|
hCellWnd |
A handle to the window that represents the cell on which the function's effect will be applied. |
|
nSubCellIndex |
A zero-based index into the image list attached to the cell specified in nCellIndex. The sub-cell with nSubCellIndex, will have its scale mode set. Pass -2 to set the scale mode of the selected sub-cell. |
|
uScaleMode |
Flag that indicates the type of the scale. Possible values are: |
|
|
Value |
Meaning |
|
CONTAINER_SCALEMODE_NORMAL |
[0x00000000] no scale mode applied. This is the defualt value. |
|
CONTAINER_SCALEMODE_FIT |
[0x00000001] The image will fit to the sub-cell boundaries. |
|
CONTAINER_SCALEMODE_FITWIDTH |
[0x00000002] The image width will fit to the sub-cell boundaires. |
|
CONTAINER_SCALEMODE_FITHEIGHT |
[0x00000003] The image height will fit to the image boundareis. |
uFlags |
Reserved for future use. Pass 0. |
Returns
SUCCESS |
The function was successful. |
< 1 |
An error occurred. Refer to Return Codes. |
Comments
Currently, there are two ways to fit an image to a cell. One is by setting the bIsFit value of DISPCELLPROPERTIES structure to true (also remembering to set the corresponding uMask value), and then sending this structure to L_DispContainerSetCellProperties. The other method is by using L_DispContainerGetCellScale and L_DispContainerSetCellScale. In order to be able to use these functions make sure that bIsFit is set to FALSE.
To get the scale of cell or sub-cell use the L_DispContainerGetCellScale function.
To set the scale of cell or sub-cell use the L_DispContainerSetCellScale function.
To set the properties of the scale action use the L_DispContainerSetActionProperties function.
To get the properties of the scale action use the L_DispContainerGetActionProperties function.
To set the scale mode of cell or sub-cell use the L_DispContainerSetCellScaleMode function.
Required DLLs and Libraries
LTIVW For a listing of the exact DLLs and Libraries needed, based on the toolkit version, refer to Files To Be Included With Your Application. |
Platforms
Windows 95 / 98 / Me; Windows 2000 / XP; Windows CE.
See Also
Example
For an example, refer to L_DispContainerBeginUpdate.