LEADTOOLS Medical (Leadtools.Dicom assembly)
LEAD Technologies, Inc

CreatePresentationLut Method








A DicomDataSet object that contains the data of the Presentation LUT to be created. The object is assumed to contain the Presentation LUT Sequence (2050,0010). If this Sequence is not present, the method will fail. This parameter can be set to a null reference (Nothing in Visual Basic) if a Presentation LUT Shape is specified using the parameter presentationLutShape.
The Presentation LUT Shape (2050,0020) of the Presentation LUT to be created. This can be set to a null reference (Nothing in Visual Basic) or it can specify an empty string if the parameter presentationLut is not a null reference.
Requests the Print SCP to create a Presentation LUT SOP Instance. .NET support
Syntax
public void CreatePresentationLut( 
   DicomDataSet presentationLut,
   string presentationLutShape
)
'Declaration
 
Public Sub CreatePresentationLut( _
   ByVal presentationLut As DicomDataSet, _
   ByVal presentationLutShape As String _
) 
'Usage
 
Dim instance As DicomPrintScu
Dim presentationLut As DicomDataSet
Dim presentationLutShape As String
 
instance.CreatePresentationLut(presentationLut, presentationLutShape)
public void CreatePresentationLut( 
   DicomDataSet presentationLut,
   string presentationLutShape
)
ObjectiveC Syntax
 function Leadtools.Dicom.DicomPrintScu.CreatePresentationLut( 
   presentationLut ,
   presentationLutShape 
)
public:
void CreatePresentationLut( 
   DicomDataSet^ presentationLut,
   String^ presentationLutShape
) 

Parameters

presentationLut
A DicomDataSet object that contains the data of the Presentation LUT to be created. The object is assumed to contain the Presentation LUT Sequence (2050,0010). If this Sequence is not present, the method will fail. This parameter can be set to a null reference (Nothing in Visual Basic) if a Presentation LUT Shape is specified using the parameter presentationLutShape.
presentationLutShape
The Presentation LUT Shape (2050,0020) of the Presentation LUT to be created. This can be set to a null reference (Nothing in Visual Basic) or it can specify an empty string if the parameter presentationLut is not a null reference.
Remarks
Two of the exceptions that can be thrown by this method are:
Exception Type Condition
DicomExceptionCode.PrintSCUFailureStatus The response of the Print SCP specifies a Failure status code; no Instance was created.
DicomExceptionCode.PrintSCUClassNotSupported The Presentation LUT SOP Class is not supported on the Association.

The method will fail if none of the parameters is supplied. If both are supplied, presentationLutShape will be ignored.

The method will not return until it receives the response of the Print SCP, or an error occurs. The method GetLastOperationStatus can be used to obtain the status code specified in the response of the Print SCP. If the method CreatePresentationLut is successful, the Presentation LUT was created successfully, with either a Success or Warning status code in the response of the Print SCP.

The method can be used to create one or more Presentation LUTs. Having a Presentation LUT created, the method GetPresentationLutInstanceUid can be used to obtain its SOP Instance UID, which in turn can be used to reference the Presentation LUT from Film Boxes and Grayscale Image Boxes. Refer to the methods CreateFilmBox, UpdateFilmBox, and UpdateImageBox.

The Print SCP can be requested to delete an existing Presentation LUT SOP Instance using the method DeletePresentationLut.

Example
For an example, refer to Associate(String,Int32,String,String,DicomPrintScuPrintManagementClassFlags).
Requirements

Target Platforms: Windows 7, Windows Vista SP1 or later, Windows XP SP3, Windows Server 2008 (Server Core not supported), Windows Server 2008 R2 (Server Core supported with SP1 or later), Windows Server 2003 SP2

See Also

Reference

DicomPrintScu Class
DicomPrintScu Members
GetPresentationLutInstanceUid Method
DeletePresentationLut Method
GetLastOperationStatus Method
CreateFilmBox Method
UpdateFilmBox Method
UpdateImageBox Method

 

 


Products | Support | Contact Us | Copyright Notices

© 2006-2012 All Rights Reserved. LEAD Technologies, Inc.

Leadtools.Dicom requires a Medical toolkit server license and unlock key. For more information, refer to: Imaging Pro/Document/Medical Features