Leadtools.Wia Namespace > WiaSession Class : AcquireToFile Method |
This parameter is only used if you are acquiring from a scanner device and the ShowUserInterface flag is NOT set. Use this parameter to specify the scanner's paper source (Feeder or Flatbed).
This flag is optional if you are using WIA 1.0 since you can change the paper source by changing the WiaPropertyId.ScannerDeviceDocumentHandlingSelect property value for the root item or by enumerating the available scanner items and passing the desired scanner item.
If you are using WIA 2.0, either enumerate the available scanner items and pass the desired scanner item; or pass null (Nothing in Visual Basic), in which case the enumeration will be performed internally and the first enumerated item will be used as the source item.
Value |
Meaning |
WiaAcquireFlags.None | Default behavior for the device image acquisition dialog box. |
WiaAcquireFlags.SingleImage | Restrict image selection to a single image in the device image acquisition dialog box. This flag is not available if you are using WIA version 2.0. |
WiaAcquireFlags.ShowUserInterface | Show the manufacturer's image acquisition dialog box. |
WiaAcquireFlags.UseCommonUI | Use the system user interface (UI), if available, rather than the vendor-supplied UI. If the system UI is not available, the vendor UI is used. |
public DialogResult AcquireToFile( IWin32Window owner, object item, WiaAcquireFlags flags )
'Declaration Public Function AcquireToFile( _ ByVal owner As IWin32Window, _ ByVal item As Object, _ ByVal flags As WiaAcquireFlags _ ) As DialogResult
'Usage Dim instance As WiaSession Dim owner As IWin32Window Dim item As Object Dim flags As WiaAcquireFlags Dim value As DialogResult value = instance.AcquireToFile(owner, item, flags)
public DialogResult AcquireToFile( IWin32Window owner, object item, WiaAcquireFlags flags )
public: DialogResult AcquireToFile( IWin32Window^ owner, Object^ item, WiaAcquireFlags flags )
This parameter is only used if you are acquiring from a scanner device and the ShowUserInterface flag is NOT set. Use this parameter to specify the scanner's paper source (Feeder or Flatbed).
This flag is optional if you are using WIA 1.0 since you can change the paper source by changing the WiaPropertyId.ScannerDeviceDocumentHandlingSelect property value for the root item or by enumerating the available scanner items and passing the desired scanner item.
If you are using WIA 2.0, either enumerate the available scanner items and pass the desired scanner item; or pass null (Nothing in Visual Basic), in which case the enumeration will be performed internally and the first enumerated item will be used as the source item.
Value |
Meaning |
WiaAcquireFlags.None | Default behavior for the device image acquisition dialog box. |
WiaAcquireFlags.SingleImage | Restrict image selection to a single image in the device image acquisition dialog box. This flag is not available if you are using WIA version 2.0. |
WiaAcquireFlags.ShowUserInterface | Show the manufacturer's image acquisition dialog box. |
WiaAcquireFlags.UseCommonUI | Use the system user interface (UI), if available, rather than the vendor-supplied UI. If the system UI is not available, the vendor UI is used. |
This function will acquire single or multiple images from the selected WIA device and save them directly to file(s).
Make sure to call WiaSession.Startup and then call any of the WiaSession.SelectDeviceDlg or WiaSession.SelectDevice functions before calling this function.
Change the AcquireOptions property members before calling this method to control the saved filenames and paths, along with other options while acquiring from the WIA source.
When performing file transfer it is optional to add the Leadtools.Wia.WiaSession.AcquireEvent event, since the event will only provide you with the saved file path and name and the percent completion of the file saving process.
Two properties within the WiaSession class will become available when using this function:
To cancel the acquire operation, add the Leadtools.Wia.WiaSession.AcquireEvent event and set the Cancel member of the WiaAcquireEventArgs to true.
Note: |
If the ShowUserInterface flag is set for any of the acquire methods, then be aware that some of the previously set/changed user properties (using any of the SetPropertyXxx or SetProperties methods) will be overwritten by the Microsoft's image acquisition dialog box. Microsoft's image acquisition dialog box sets its own initialization properties like the current intent (image type), selected area (left, top, width and height), paper source and duplex mode, ...etc.
To suppress the manufacturer's image acquisition dialog and acquire directly from the specified source item through the item parameter using the values set through the SetPropertyXxx and SetProperties methods, do not set the ShowUserInterface flag. |
Note: | While running a Win32 version application that calls this function on Windows VISTA 64-Bit we have noticed that the FilesCount and FilesPaths properties will not be updated with the required information. This is a known limitation of Microsoft's WIA toolkit. |
Note: | If you are using WIA 2.0 while the ShowUserInterface flag is set then it is not necessary to add the Leadtools.Wia.WiaSession.AcquireEvent event. Microsoft's WIA 2.0 Acquire dialog does not provide an event but performs all of the processing and returns with the number of files that were saved along with their paths through the FilesCount and FilesPaths properties. |
For more information, refer to How to Acquire from the WIA Source.
Public Sub AcquireToFileExample(ByVal parent As IWin32Window) If (Not WiaSession.IsAvailable(WiaVersion.Version1)) Then MessageBox.Show("WIA version 1.0 not installed.") Return End If Dim session As WiaSession = New WiaSession() session.Startup(WiaVersion.Version1) Dim res As DialogResult = session.SelectDeviceDlg(parent, WiaDeviceType.Default, WiaSelectSourceFlags.NoDefault) If res <> DialogResult.OK Then MessageBox.Show("Error selecting WIA device.") session.Shutdown() Return End If ' Initialize and fill the required fields from the WiaAcquireOptions structure Dim wiaAcquireOptions As WiaAcquireOptions = wiaAcquireOptions.Empty wiaAcquireOptions.FileName = Path.Combine(LEAD_VARS.ImagesDir, "WiaTest.bmp") wiaAcquireOptions.OverwriteExisting = True wiaAcquireOptions.Append = False wiaAcquireOptions.SaveToOneFile = False session.AcquireOptions = wiaAcquireOptions AddHandler session.AcquireFileEvent, AddressOf session_AcquireFileEvent session.AcquireToFile(parent, Nothing, WiaAcquireFlags.ShowUserInterface Or WiaAcquireFlags.UseCommonUI) ' Display listing of all paths and filenames for the saved files(s). If session.FilesCount > 0 Then Dim strMsg As String = "Acquired page(s) were saved to:" & Constants.vbLf + Constants.vbLf Dim i As Integer = 0 Do While i < session.FilesCount Dim strTemp As String = String.Format("{0}" & Constants.vbLf, session.FilesPaths(i)) strMsg &= strTemp i += 1 Loop MessageBox.Show(strMsg) End If RemoveHandler session.AcquireFileEvent, AddressOf session_AcquireFileEvent session.Shutdown() End Sub Public Sub session_AcquireFileEvent(ByVal sender As Object, ByVal e As WiaAcquireFileEventArgs) Console.WriteLine(e.Percent) End Sub Public NotInheritable Class LEAD_VARS Public Const ImagesDir As String = "C:\Users\Public\Documents\LEADTOOLS Images" End Class
public void AcquireToFileExample(IWin32Window parent) { if (!WiaSession.IsAvailable(WiaVersion.Version1)) { MessageBox.Show("WIA version 1.0 not installed."); return; } WiaSession wiaSession = new WiaSession(); wiaSession.Startup(WiaVersion.Version1); DialogResult res = wiaSession.SelectDeviceDlg(parent, WiaDeviceType.Default, WiaSelectSourceFlags.NoDefault); if (res != DialogResult.OK) { MessageBox.Show("Error selecting WIA device."); wiaSession.Shutdown(); return; } // Initialize and fill the required fields from the WiaAcquireOptions structure WiaAcquireOptions wiaAcquireOptions = WiaAcquireOptions.Empty; wiaAcquireOptions.FileName = Path.Combine(LEAD_VARS.ImagesDir, "WiaTest.bmp"); wiaAcquireOptions.OverwriteExisting = true; wiaAcquireOptions.Append = false; wiaAcquireOptions.SaveToOneFile = false; wiaSession.AcquireOptions = wiaAcquireOptions; wiaSession.AcquireFileEvent += new EventHandler<WiaAcquireFileEventArgs>(wiaSession_AcquireFileEvent); wiaSession.AcquireToFile(parent, null, WiaAcquireFlags.ShowUserInterface | WiaAcquireFlags.UseCommonUI); // Display a listing of all paths and filenames for the saved files(s). if(wiaSession.FilesCount > 0) { string strMsg = "Acquired page(s) were saved to:\n\n"; for (int i = 0; i < wiaSession.FilesCount; i++) { string strTemp = string.Format("{0}\n", wiaSession.FilesPaths[i]); strMsg += strTemp; } MessageBox.Show(strMsg); } wiaSession.AcquireFileEvent -= new EventHandler<WiaAcquireFileEventArgs>(wiaSession_AcquireFileEvent); wiaSession.Shutdown(); } public void wiaSession_AcquireFileEvent(object sender, WiaAcquireFileEventArgs e) { Console.WriteLine(e.Percent); } static class LEAD_VARS { public const string ImagesDir = @"C:\Users\Public\Documents\LEADTOOLS Images"; }
Target Platforms: Windows 7, Windows Vista SP1 or later, Windows XP SP3, Windows Server 2008 (Server Core not supported), Windows Server 2008 R2 (Server Core supported with SP1 or later), Windows Server 2003 SP2