Available in LEADTOOLS Medical Imaging toolkits. |
#include "ltdic.h"
L_UINT32 LDicomNet::SetMaxCommBlockLengthISCL (nMaxCommBlockLength);
L_UINT32 nMaxCommBlockLength; |
/* maximum communication block length */ |
Sets the maximum communication block length that can be sent/received by the current entity. This function is available in the PACS Imaging toolkits.
Parameter |
Description |
nMaxCommBlockLength |
Size of the communication block length. |
Returns
DICOM_SUCCESS |
Success. The maximum communication block length was set. During mutual authentication, the client and server will agree to use the smaller communication block size of the two. |
DICOM_ERROR |
An error occurred. This usually occurs if the nMaxCommBlockLength was too small for the maximum standard packet size (168 bytes). |
Comments
An ISCL communication block contains a 32-byte header, followed by data, if data is included.
Please note that the size of the ISCL packets is 32 bytes larger than the communication block length, because of the header.
Required DLLs and Libraries
LTDIC For a listing of the exact DLLs and Libraries needed, based on the toolkit version, refer to Files To Be Included With Your Application |
Win32, x64
See Also
Example
L_INT LDicomNet_SetMaxCommBlockLengthISCLExample() { L_INT nRet; // LMyDicomNet is derived from LDicomNet LMyDicomNet *pDicomNet; pDicomNet = new LMyDicomNet(TEXT(""), DICOM_SECURE_ISCL); nRet =pDicomNet->SetMaxCommBlockLengthISCL(8160); if(nRet !=DICOM_SUCCESS) return nRet; // size of the blocks sent to the network // layer will be 8192 bytes (a 32-bytes header is added) return DICOM_SUCCESS; }