LEADTOOLS Medical (Leadtools.Dicom assembly)

DeletePresentationLut Method

Show in webframe







The SOP Instance UID of the Presentation LUT to be deleted. The method will fail if this is a null reference (Nothing in Visual Basic) or if an empty string is specified.
Requests the Print SCP to delete the specified Presentation LUT SOP Instance.
Syntax
public void DeletePresentationLut( 
   string presentationLutInstanceUid
)
'Declaration
 
Public Sub DeletePresentationLut( _
   ByVal presentationLutInstanceUid As String _
) 
'Usage
 
Dim instance As DicomPrintScu
Dim presentationLutInstanceUid As String
 
instance.DeletePresentationLut(presentationLutInstanceUid)
public void DeletePresentationLut( 
   string presentationLutInstanceUid
)

            

            
 function Leadtools.Dicom.DicomPrintScu.DeletePresentationLut( 
   presentationLutInstanceUid 
)
public:
void DeletePresentationLut( 
   String^ presentationLutInstanceUid
) 

Parameters

presentationLutInstanceUid
The SOP Instance UID of the Presentation LUT to be deleted. The method will fail if this is a null reference (Nothing in Visual Basic) or if an empty string is specified.
Remarks
Two of the exceptions that can be thrown by this method are:
Exception Type Condition
DicomExceptionCode.PrintSCUFailureStatus The response of the Print SCP specifies a Failure status code.
DicomExceptionCode.PrintSCUClassNotSupported The Presentation LUT SOP Class is not supported on the Association.

The Presentation LUT specified (by the SOP Instance UID) must be an existing one. Refer to the method CreatePresentationLut for creating Presentation LUTs.

The method will not return until it receives the response of the Print SCP, or an error occurs. The method GetLastOperationStatus can be used to obtain the status code specified in the response of the Print SCP. If the method DeletePresentationLut is successful, the specified Presentation LUT was deleted successfully, with either a Success or Warning status code in the response of the Print SCP.

Once a Presentation LUT is deleted, it can no longer be referenced by Film Boxes and Image Boxes.

Example
For an example, refer to Associate(String,Int32,String,String,DicomPrintScuPrintManagementClassFlags).
Requirements

Target Platforms

See Also

Reference

DicomPrintScu Class
DicomPrintScu Members
CreatePresentationLut Method
GetPresentationLutInstanceUid Method
GetLastOperationStatus Method

 

 


Products | Support | Contact Us | Copyright Notices
© 2006-2014 All Rights Reserved. LEAD Technologies, Inc.

Leadtools.Dicom requires a Medical toolkit server license and unlock key. For more information, refer to: Imaging Pro/Document/Medical Features