←Select platform

GetPropertyLong Method

Syntax

C#
VB
C++
public int GetPropertyLong( 
   object item, 
   string propertyIdName, 
   WiaPropertyId propertyId 
) 
  
Public Function GetPropertyLong( _ 
   ByVal item As Object, _ 
   ByVal propertyIdName As String, _ 
   ByVal propertyId As Leadtools.Wia.WiaPropertyId _ 
) As Integer 
public: 
int GetPropertyLong(  
   Object^ item, 
   String^ propertyIdName, 
   Leadtools.Wia.WiaPropertyId propertyId 
)  

Parameters

item
Handle to the item which represents the item having the property. You can retrieve this parameter by either calling the GetRootItem method to get the device's root item itself or by enumerating the child items of the device through a call to EnumChildItems method.

propertyIdName
This string should contain the equivalent property Id string for the WIA property ID. Use the see GetPropertyIdString method to get this string for the property ID.

If you passed null for this parameter then the WIA toolkit will use the property ID passed through the third parameter

propertyId**; otherwise this parameters will be used whether or not you passed a valid property ID through the propertyId parameter

propertyId
The property ID for the value being sought. For a list of available property IDs, refer to WiaPropertyId.

This parameter is required only if the second parameter "propertyIdName"is null; otherwise you can pass 0 for this parameter.

Return Value

The WIA long value.

Remarks

Call this function to retrieve the Long value for any WIA property of the types mentioned (for instance, WiaPropertyId.ScannerDeviceDocumentHandlingSelect , WiaPropertyId.DeviceInfoDevTypewiapropertyid.itembuffersize , ...etc).

For more information, refer to Managing WIA Sources.

Example

C#
VB
using Leadtools; 
using Leadtools.Codecs; 
using Leadtools.Wia; 
 
WiaSession myWia_Session; 
public void GetPropertyLongExample(IntPtr parent) 
{ 
   if (!WiaSession.IsAvailable(WiaVersion.Version1)) 
   { 
      MessageBox.Show("WIA version 1.0 not installed."); 
      return; 
   } 
 
   myWia_Session = new WiaSession(); 
   myWia_Session.Startup(WiaVersion.Version1); 
 
   DialogResult res = myWia_Session.SelectDeviceDlg(parent, WiaDeviceType.Default, WiaSelectSourceFlags.NoDefault); 
   if (res != DialogResult.OK) 
   { 
      MessageBox.Show("Error selecting WIA device."); 
      myWia_Session.Shutdown(); 
      return; 
   } 
 
   object rootItem = myWia_Session.GetRootItem(null); 
   if (rootItem != null) 
   { 
      myWia_Session.EnumItemsEvent += new EventHandler<WiaEnumItemsEventArgs>(wiaSession_EnumItemsEvent4); 
 
      myWia_Session.EnumChildItems(rootItem); 
 
      myWia_Session.EnumItemsEvent -= new EventHandler<WiaEnumItemsEventArgs>(wiaSession_EnumItemsEvent4); 
   } 
 
   myWia_Session.Shutdown(); 
} 
 
void wiaSession_EnumItemsEvent4(object sender, WiaEnumItemsEventArgs e) 
{ 
   if (e.Item != null) 
   { 
      // Read the document handling select property. 
      int longValue = myWia_Session.GetPropertyLong(e.Item, null, WiaPropertyId.ScannerDeviceDocumentHandlingSelect); 
 
      // If the Feeder is not selected then select the Feeder. 
      if ((longValue & (int)WiaScanningModeFlags.Feeder) != (int)WiaScanningModeFlags.Feeder) 
      { 
         longValue = (int)WiaScanningModeFlags.Feeder; 
         myWia_Session.SetPropertyLong(e.Item, null, WiaPropertyId.ScannerDeviceDocumentHandlingSelect, longValue); 
      } 
 
      myWia_Session.FreeItem(e.Item); 
   } 
} 
Imports Leadtools 
Imports Leadtools.Codecs 
Imports Leadtools.Wia 
 
Dim myWia_Session As WiaSession 
<TestMethod()> _ 
Public Sub GetPropertyLongExample(ByVal parent As IntPtr) 
   If (Not wiaSession.IsAvailable(WiaVersion.Version1)) Then 
      MessageBox.Show("WIA version 1.0 not installed.") 
      Return 
   End If 
 
   myWia_Session = New WiaSession() 
   myWia_Session.Startup(WiaVersion.Version1) 
 
   Dim res As DialogResult = myWia_Session.SelectDeviceDlg(parent, WiaDeviceType.Default, WiaSelectSourceFlags.NoDefault) 
   If res <> DialogResult.OK Then 
      MessageBox.Show("Error selecting WIA device.") 
      myWia_Session.Shutdown() 
      Return 
   End If 
 
   Dim rootItem As Object = myWia_Session.GetRootItem(Nothing) 
   If Not rootItem Is Nothing Then 
      AddHandler myWia_Session.EnumItemsEvent, AddressOf session_EnumItemsEvent4 
 
      myWia_Session.EnumChildItems(rootItem) 
 
      RemoveHandler myWia_Session.EnumItemsEvent, AddressOf session_EnumItemsEvent4 
   End If 
 
   myWia_Session.Shutdown() 
End Sub 
 
Private Sub session_EnumItemsEvent4(ByVal sender As Object, ByVal e As WiaEnumItemsEventArgs) 
   If Not e.Item Is Nothing Then 
      ' Read the document handling select property. 
      Dim longValue As Integer = myWia_Session.GetPropertyLong(e.Item, Nothing, WiaPropertyId.ScannerDeviceDocumentHandlingSelect) 
 
      ' If Feeder is not selected then select the Feeder. 
      If (longValue And CInt(WiaScanningModeFlags.Feeder)) <> CInt(WiaScanningModeFlags.Feeder) Then 
         longValue = CInt(WiaScanningModeFlags.Feeder) 
         myWia_Session.SetPropertyLong(e.Item, Nothing, WiaPropertyId.ScannerDeviceDocumentHandlingSelect, longValue) 
      End If 
 
      myWia_Session.FreeItem(e.Item) 
   End If 
End Sub 

Requirements

Target Platforms

Help Version 19.0.2017.10.27
Products | Support | Contact Us | Copyright Notices
© 1991-2017 LEAD Technologies, Inc. All Rights Reserved.

Leadtools.Wia Assembly