LImageViewerCell::CalibrateCell

#include "ltwrappr.h"

L_INT LImageViewerCell::CalibrateCell(nSubCellIndex, dLength, uUnit, dTargetLength, uTargetUnit, uFlags)

Calibrates the cell or sub-cell without having to use the annotation ruler, to calibrate using annotation ruler use the LImageViewerCell::CalibrateRuler function.

Parameters

L_INT nSubCellIndex

A zero-based index into the image list attached to the cell. This sub-cell will be calibrated. Pass -1 to apply this effect on all sub-cells. Pass -2 to apply this effect on the selected sub-cell.

L_DOUBLE dLength

Value that represents the old length of the virtual ruler.

L_UINT uUnit

Value that specifies the unit of measure for the virtual ruler length. Possible values are:

Value Meaning
CONTAINER_RULERUNIT_INCHES [0] Inches.
CONTAINER_RULERUNIT_FEET [1] Feet.
CONTAINER_RULERUNIT_MICROMETERS [2] Micrometers.
CONTAINER_RULERUNIT_MILLIMETERS [3] Millimeters.
CONTAINER_RULERUNIT_CENTIMETERS [4] Centimeters. This is the default value.
CONTAINER_RULERUNIT_METERS [5] Meters.

L_DOUBLE dTargetLength

Value that represents the length to be assigned to the virtual ruler. The unit of measure for the length is specified by the value of the uTargetUnit parameter.

L_UINT uTargetUnit

Value that specifies the unit of measure for the virtual ruler length. Possible values are:

Value Meaning
CONTAINER_RULERUNIT_INCHES [0] Inches.
CONTAINER_RULERUNIT_FEET [1] Feet.
CONTAINER_RULERUNIT_MICROMETERS [2] Micrometers.
CONTAINER_RULERUNIT_MILLIMETERS [3] Millimeters.
CONTAINER_RULERUNIT_CENTIMETERS [4] Centimeters. This is the default value.
CONTAINER_RULERUNIT_METERS [5] Meters.

 

L_UINT uFlags

Flags that indicate the direction to which the calibration is applied. Possible values are:

Value Meaning
CONTAINER_CALIBRATERULER_BOTH [0] Calibrate both axes. This is the default value.
CONTAINER_CALIBRATERULER_VERTICAL [1] Calibrate only the vertical axis.
CONTAINER_CALIBRATERULER_HORIZONTAL [2] Calibrate only the horizontal axis.

The following flags that determine whether to apply the feature on the one cell only, or more than one cell. This value can only be used when the cell is attached to the LImageViewer through the function LImageViewer::InsertCell. Possible values are:

Value Meaning
CELL_APPLYTOTHIS [0x00000000] Apply the feature to this cell only.
CELL_APPLYTOALL [0x10000000] Apply the feature to all the cells in the Image Viewer.
CELL_APPLYTOSELECTED [0x20000000] Apply the feature to the selected cells in the Image Viewer.

Returns

Value Meaning
SUCCESS The function was successful.
< 1 An error occurred. Refer to Return Codes.

Comments

This function does not require that the annotation ruler to be present in order to calibrate the cell.

The user is expected to send a length along with the unit of measure, and then send a new length with the new unit of measure for the cell being calibrated.

To obtain the unit of measure of the viewer, call the LImageViewerCell::GetRulerUnit function.

To change the unit of measure unit of the viewer, call the LImageViewerCell::SetRulerUnit function.

Required DLLs and Libraries

See Also

Functions

Topics

Example

This example calibrates the first frame of the first cell.

L_INT LImageViewer_CalibrateCellExample(LImageViewerCell& ImageViewerCell) 
{ 
   L_INT nRet; 
 
   nRet = ImageViewerCell.CalibrateCell(0, 1, CONTAINER_RULERUNIT_CENTIMETERS, 2, CONTAINER_RULERUNIT_CENTIMETERS, 0); 
 
   return nRet; 
} 

Help Version 20.0.2020.4.2
Products | Support | Contact Us | Intellectual Property Notices
© 1991-2020 LEAD Technologies, Inc. All Rights Reserved.

LEADTOOLS Medical Image Viewer C++ Class Library Help