Sets the attributes that describe the "Window Center" and "Window Width".
public void SetWindow(
int frameIndex,
int index,
DicomWindowAttributes attributes,
DicomSetImageFlags flags
)
Public Overloads Sub SetWindow( _
ByVal frameIndex As Integer, _
ByVal index As Integer, _
ByVal attributes As Leadtools.Dicom.DicomWindowAttributes, _
ByVal flags As Leadtools.Dicom.DicomSetImageFlags _
)
public void SetWindow(
int frameIndex,
int index,
Leadtools.Dicom.DicomWindowAttributes attributes,
Leadtools.Dicom.DicomSetImageFlags flags
)
public void setWindow(int frameIndex, int index, DicomWindowAttributes attributes, int dicomSetImageFlags)
function Leadtools.Dicom.DicomDataSet.SetWindow(Int32,Int32,DicomWindowAttributes,DicomSetImageFlags)(
frameIndex ,
index ,
attributes ,
flags
)
public:
void SetWindow(
int frameIndex,
int index,
Leadtools.Dicom.DicomWindowAttributes^ attributes,
Leadtools.Dicom.DicomSetImageFlags flags
)
frameIndex
A zero-based index that identifies the frame number in the dataset. If the dataset does not support Multi-frames, this parameter is ignored.
index
The zero-based index of the window center, window width value, to update. According to the DICOM standard, if multiple values are present for the window center and window width, both attributes shall have the same number of values and shall be considered as pairs.
attributes
The window-related attributes to set.
flags
determines how the VOI LUT is set
This method will set the attributes that describe window center and window width.
If "Window Center" (0028,1050) does not already exist in the Data Set, this method will insert it and set its value to WindowCenter.
If "Window Width" (0028,1051) does not already exist in the Data Set, this method will isnert it and set its value to WindowWidth.
The Multi-frame Functional Groups module may have a Shared Functional Groups Sequence item, and/or a Per-frame Functional Groups Sequence item. Either of these items may have a Frame VOI LUT Sequence (0028,9132) item. The uFlags parameter can be used to add or modify existing information in the Frame VOI LUT Sequence. The following flags are used only if the Frame VOI LUT Sequence does not already exist.
The specific elements that are read or updated when using these flags are shown below: (0028,9132) Frame VOI LUT Sequence Child Elements
Tag | Name |
(0028,1050) | Window Center |
(0028,1051) | Window Width |
(0028,1055) | Window Center & Width Explanation |
Valid flags are DicomSetImageFlags.None, DicomSetImageFlags.MfgOverwriteShared, DicomSetImageFlags.MfgVoiLutPerFrame, DicomSetImageFlags.MfgVoiLutShared. All other flags are ignored. For a detailed discussion on Multi-frame Functional Groups see the topic Multi-frame Functional Groups.
This example will initialize a new DICOM command set that supports Multi-frame functional groups Two VOI LUT will be added to the dataset at the per frame level The VOI LUT from the second frame is retrieved Finally, the VOI LUT from the second frame is deleted
using Leadtools;
using Leadtools.Dicom;
///
void DicomDataSet_SetWindowExample()
{
DicomDataSet ds = new DicomDataSet();
DicomDataSetInitializeFlags flags =
DicomDataSetInitializeFlags.ExplicitVR |
DicomDataSetInitializeFlags.LittleEndian |
DicomDataSetInitializeFlags.AddMandatoryElementsOnly |
DicomDataSetInitializeFlags.AddMandatoryModulesOnly
;
// Initialize with class that supports multiframe functional groups
ds.Initialize(DicomClassType.EnhancedMRImageStorage, flags);
// Delete these items -- they will get added again later in the sample
// * Shared Functional Group2 Sequence
// * Per-frame Functional Group2 Sequence
DicomElement element = ds.FindFirstElement(null, DicomTag.PerFrameFunctionalGroupsSequence, false);
if (element != null)
ds.DeleteElement(element);
element = ds.FindFirstElement(null, DicomTag.SharedFunctionalGroupsSequence, false);
if (element != null)
ds.DeleteElement(element);
// Add a VOI LUT on 0th frame
DicomWindowAttributes windowAttributes = new DicomWindowAttributes();
windowAttributes.WindowCenter = 32767;
windowAttributes.WindowWidth = 65535;
windowAttributes.Explanation = "frame 0";
ds.SetWindow(0, 0, windowAttributes, DicomSetImageFlags.MfgVoiLutPerFrame);
// Add a second VOI LUT on the 1st frame
windowAttributes.WindowCenter = 32000;
windowAttributes.WindowWidth = 60000;
windowAttributes.Explanation = "frame 1";
ds.SetWindow(1, 0, windowAttributes, DicomSetImageFlags.MfgVoiLutPerFrame);
// Retrieve the modality LUT attributes from second frame (frameIndex == 1)
DicomWindowAttributes windowAttributes2 = ds.GetWindow(1, 0);
string sMsg = string.Format("Window Center: {0}\nWindowWidth: {1}\nExplanation {2}",
windowAttributes.WindowCenter,
windowAttributes.WindowWidth,
windowAttributes.Explanation);
MessageBox.Show(sMsg);
// Finally, delete the second VOI LUT
ds.DeleteWindow(1, DicomSetImageFlags.None);
// Save the file
ds.Save(Path.Combine(LEAD_VARS.ImagesDir, "Test.dcm"), DicomDataSetSaveFlags.None);
}
static class LEAD_VARS
{
public const string ImagesDir = @"C:\Users\Public\Documents\LEADTOOLS Images";
}
Imports Leadtools
Imports Leadtools.Dicom
'''
Private Sub DicomDataSet_SetWindowExample()
Dim ds As DicomDataSet = New DicomDataSet()
Dim flags As DicomDataSetInitializeFlags = DicomDataSetInitializeFlags.ExplicitVR Or DicomDataSetInitializeFlags.LittleEndian Or
DicomDataSetInitializeFlags.AddMandatoryElementsOnly Or DicomDataSetInitializeFlags.AddMandatoryModulesOnly
' Initialize with class that supports multiframe functional groups
ds.Initialize(DicomClassType.EnhancedMRImageStorage, flags)
' Delete these items -- they will get added again later in the sample
' * Shared Functional Group2 Sequence
' * Per-frame Functional Group2 Sequence
Dim element As DicomElement = ds.FindFirstElement(Nothing, DicomTag.PerFrameFunctionalGroupsSequence, False)
If Not element Is Nothing Then
ds.DeleteElement(element)
End If
element = ds.FindFirstElement(Nothing, DicomTag.SharedFunctionalGroupsSequence, False)
If Not element Is Nothing Then
ds.DeleteElement(element)
End If
' Add a VOI LUT on 0th frame
Dim windowAttributes As DicomWindowAttributes = New DicomWindowAttributes()
windowAttributes.WindowCenter = 32767
windowAttributes.WindowWidth = 65535
windowAttributes.Explanation = "frame 0"
ds.SetWindow(0, 0, windowAttributes, DicomSetImageFlags.MfgVoiLutPerFrame)
' Add a second VOI LUT on the 1st frame
windowAttributes.WindowCenter = 32000
windowAttributes.WindowWidth = 60000
windowAttributes.Explanation = "frame 1"
ds.SetWindow(1, 0, windowAttributes, DicomSetImageFlags.MfgVoiLutPerFrame)
' Retrieve the modality LUT attributes from second frame (frameIndex == 1)
Dim windowAttributes2 As DicomWindowAttributes = ds.GetWindow(1, 0)
Dim sMsg As String = String.Format("Window Center: {0}" & Constants.vbLf & "WindowWidth: {1}" & Constants.vbLf & "Explanation {2}",
windowAttributes.WindowCenter, windowAttributes.WindowWidth, windowAttributes.Explanation)
MessageBox.Show(sMsg)
' Finally, delete the second VOI LUT
ds.DeleteWindow(1, DicomSetImageFlags.None)
' Save the file
ds.Save(Path.Combine(LEAD_VARS.ImagesDir, "Test.dcm"), DicomDataSetSaveFlags.None)
End Sub
Public NotInheritable Class LEAD_VARS
Public Const ImagesDir As String = "C:\Users\Public\Documents\LEADTOOLS Images"
End Class
using Leadtools;
using Leadtools.Dicom;
using Leadtools.Examples;
void DicomDataSet_SetWindowExample(Stream outputStream)
{
DicomDataSet ds = new DicomDataSet();
DicomDataSetInitializeFlags flags =
DicomDataSetInitializeFlags.ExplicitVR |
DicomDataSetInitializeFlags.LittleEndian |
DicomDataSetInitializeFlags.AddMandatoryElementsOnly |
DicomDataSetInitializeFlags.AddMandatoryModulesOnly
;
// Initialize with class that supports multiframe functional groups
ds.Initialize(DicomClassType.EnhancedMRImageStorage, flags);
// Delete these items -- they will get added again later in the sample
// * Shared Functional Group2 Sequence
// * Per-frame Functional Group2 Sequence
DicomElement element = ds.FindFirstElement(null, DicomTag.PerFrameFunctionalGroupsSequence, false);
if (element != null)
ds.DeleteElement(element);
element = ds.FindFirstElement(null, DicomTag.SharedFunctionalGroupsSequence, false);
if (element != null)
ds.DeleteElement(element);
// Add a VOI LUT on 0th frame
DicomWindowAttributes windowAttributes = new DicomWindowAttributes();
windowAttributes.WindowCenter = 32767;
windowAttributes.WindowWidth = 65535;
windowAttributes.Explanation = "frame 0";
ds.SetWindow(0, 0, windowAttributes, DicomSetImageFlags.MfgVoiLutPerFrame);
// Add a second VOI LUT on the 1st frame
windowAttributes.WindowCenter = 32000;
windowAttributes.WindowWidth = 60000;
windowAttributes.Explanation = "frame 1";
ds.SetWindow(1, 0, windowAttributes, DicomSetImageFlags.MfgVoiLutPerFrame);
// Retrieve the modality LUT attributes from second frame (frameIndex == 1)
DicomWindowAttributes windowAttributes2 = ds.GetWindow(1, 0);
string sMsg = string.Format("Window Center: {0}\nWindowWidth: {1}\nExplanation {2}",
windowAttributes.WindowCenter,
windowAttributes.WindowWidth,
windowAttributes.Explanation);
Debug.WriteLine(sMsg);
// Finally, delete the second VOI LUT
ds.DeleteWindow(1, DicomSetImageFlags.None);
// Save the file
ds.Save(outputStream, DicomDataSetSaveFlags.None);
}
Imports Leadtools
Imports Leadtools.Dicom
Private Sub DicomDataSet_SetWindowExample(ByVal outputStream As Stream)
Dim ds As DicomDataSet = New DicomDataSet()
Dim flags As DicomDataSetInitializeFlags = DicomDataSetInitializeFlags.ExplicitVR Or
DicomDataSetInitializeFlags.LittleEndian Or
DicomDataSetInitializeFlags.AddMandatoryElementsOnly Or
DicomDataSetInitializeFlags.AddMandatoryModulesOnly
' Initialize with class that supports multiframe functional groups
ds.Initialize(DicomClassType.EnhancedMRImageStorage, flags)
' Delete these items -- they will get added again later in the sample
' * Shared Functional Group2 Sequence
' * Per-frame Functional Group2 Sequence
Dim element As DicomElement = ds.FindFirstElement(Nothing, DicomTag.PerFrameFunctionalGroupsSequence, False)
If Not element Is Nothing Then
ds.DeleteElement(element)
End If
element = ds.FindFirstElement(Nothing, DicomTag.SharedFunctionalGroupsSequence, False)
If Not element Is Nothing Then
ds.DeleteElement(element)
End If
' Add a VOI LUT on 0th frame
Dim windowAttributes As DicomWindowAttributes = New DicomWindowAttributes()
windowAttributes.WindowCenter = 32767
windowAttributes.WindowWidth = 65535
windowAttributes.Explanation = "frame 0"
ds.SetWindow(0, 0, windowAttributes, DicomSetImageFlags.MfgVoiLutPerFrame)
' Add a second VOI LUT on the 1st frame
windowAttributes.WindowCenter = 32000
windowAttributes.WindowWidth = 60000
windowAttributes.Explanation = "frame 1"
ds.SetWindow(1, 0, windowAttributes, DicomSetImageFlags.MfgVoiLutPerFrame)
' Retrieve the modality LUT attributes from second frame (frameIndex == 1)
Dim windowAttributes2 As DicomWindowAttributes = ds.GetWindow(1, 0)
Dim sMsg As String = String.Format("Window Center: {0}" _
& Constants.vbLf _
& "WindowWidth: {1}" _
& Constants.vbLf _
& "Explanation {2}",
windowAttributes.WindowCenter,
windowAttributes.WindowWidth,
windowAttributes.Explanation)
Debug.WriteLine(sMsg)
' Finally, delete the second VOI LUT
ds.DeleteWindow(1, DicomSetImageFlags.None)
' Save the file
ds.Save(outputStream, DicomDataSetSaveFlags.None)
End Sub
Raster .NET | C API | C++ Class Library | JavaScript HTML5
Document .NET | C API | C++ Class Library | JavaScript HTML5
Medical .NET | C API | C++ Class Library | JavaScript HTML5
Medical Web Viewer .NET