public int XModule { get; set; }
@property (nonatomic, assign) NSInteger xModule;
XModule # get and set (PharmaCodeBarcodeWriteOptions)
An Int32 that indicates the size of the smallest module when writing a PhamraCode barcode in thousandths of an inch. Must be a value greater than or equal to 0. The default value is 30 (0.03 of an inch).
Only used if the value of UseXModule is set to true, otherwise, the module size is calculated from the data size BarcodeData.Bounds).
If the value is too small, a minimum of 2 pixels will be used regardless of the value set in XModule.
For more information, refer to Writing Barcodes - Bounds and XModule.
using Leadtools;
using Leadtools.Codecs;
using Leadtools.Barcode;
using Leadtools.ImageProcessing;
public void BarcodeWriteOptions_Example()
{
// This example uses derived classes from the abstract class BarcodeWriteOptions to set the barcode write options.
// For example: OneDBarcodeWriteOptions, GS1DatabarStackedBarcodeWriteOptions,
// PatchCodeBarcodeWriteOptions, PostNetPlanetBarcodeWriteOptions are derived
// from the abstract class BarcodeWriteOptions
// Create a directory to store the images we will create
string outDir = Path.Combine(LEAD_VARS.ImagesDir, "MyBarcodes");
if (Directory.Exists(outDir))
{
Directory.Delete(outDir, true);
}
Directory.CreateDirectory(outDir);
int resolution = 300;
// Create a Barcode engine
BarcodeEngine engine = new BarcodeEngine();
// Get the Barcode writer
BarcodeWriter writer = engine.Writer;
// All 1D options have the UseXModule set to false by default, we need to set it to true
// so we can calculate the default size. We will change the default options so we can
// pass null to CalculateBarcodeDataBounds and WriteBarcode below
// For all Standard 1D.
OneDBarcodeWriteOptions oneDWriteOptions = writer.GetDefaultOptions(BarcodeSymbology.UPCA) as OneDBarcodeWriteOptions;
oneDWriteOptions.UseXModule = true;
// All GS1 Databar Stacked
GS1DatabarStackedBarcodeWriteOptions gs1DatabarStackedWriteOptions = writer.GetDefaultOptions(BarcodeSymbology.GS1DatabarStacked) as GS1DatabarStackedBarcodeWriteOptions;
gs1DatabarStackedWriteOptions.UseXModule = true;
// Patch Code
PatchCodeBarcodeWriteOptions patchCodeWriteOptions = writer.GetDefaultOptions(BarcodeSymbology.PatchCode) as PatchCodeBarcodeWriteOptions;
patchCodeWriteOptions.UseXModule = true;
// All PostNet/Planet
PostNetPlanetBarcodeWriteOptions postNetPlanetWriteOptions = writer.GetDefaultOptions(BarcodeSymbology.PostNet) as PostNetPlanetBarcodeWriteOptions;
postNetPlanetWriteOptions.UseXModule = true;
// Pharma code
PharmaCodeBarcodeWriteOptions pharmaCodeBarcodeWriteOptions = writer.GetDefaultOptions(BarcodeSymbology.PharmaCode) as PharmaCodeBarcodeWriteOptions;
pharmaCodeBarcodeWriteOptions.UseXModule = true;
pharmaCodeBarcodeWriteOptions.XModule = 30;
// We will use this object to save files
using (RasterCodecs codecs = new RasterCodecs())
{
// Get all the available write symbologies
BarcodeSymbology[] symbologies = writer.GetAvailableSymbologies();
foreach (BarcodeSymbology symbology in symbologies)
{
Console.WriteLine("Processing {0}", symbology);
// Create the default data for this symbology
BarcodeData data = BarcodeData.CreateDefaultBarcodeData(symbology);
// Calculate its size with default options
writer.CalculateBarcodeDataBounds(LeadRect.Empty, resolution, resolution, data, null);
// Create an image to write the data to
LeadRect pixels = data.Bounds;
using (RasterImage image = RasterImage.Create(pixels.Width, pixels.Height, 1, resolution, RasterColor.FromKnownColor(RasterKnownColor.White)))
{
// Write the barcode with default options
writer.WriteBarcode(image, data, null);
// Save it
string outFileName = Path.Combine(outDir, symbology + ".tif");
codecs.Save(image, outFileName, RasterImageFormat.Tif, 1);
}
}
}
}
static class LEAD_VARS
{
public const string ImagesDir = @"C:\LEADTOOLS23\Resources\Images";
}
import java.io.Console;
import java.io.File;
import java.io.IOException;
import java.nio.file.Path;
import java.time.LocalDateTime;
import org.apache.lucene.store.Directory;
import org.junit.*;
import org.junit.runner.JUnitCore;
import org.junit.runner.Result;
import org.junit.runner.notification.Failure;
import static org.junit.Assert.*;
import leadtools.*;
import leadtools.barcode.*;
import leadtools.codecs.*;
public void barcodeWriteOptionsExample() {
// Create a directory to store the images we will create
String LEAD_VARS_ImagesDir = "C:\\LEADTOOLS23\\Resources\\Images";
String outDir = combine(LEAD_VARS_ImagesDir, "MyBarcodes");
File dir = new File(outDir);
if (dir.exists()) {
dir.delete();
}
dir.mkdirs();
int resolution = 300;
// Create a Barcode engine
BarcodeEngine engine = new BarcodeEngine();
// Get the Barcode writer
BarcodeWriter writer = engine.getWriter();
// All 1D options have the UseXModule set to false by default, we need to set it
// to true
// so we can calculate the default size. We will change the default options so
// we can
// pass null to CalculateBarcodeDataBounds and WriteBarcode below
// For all Standard 1D.
OneDBarcodeWriteOptions oneDWriteOptions = (OneDBarcodeWriteOptions) writer
.getDefaultOptions(BarcodeSymbology.UPC_A);
oneDWriteOptions.setUseXModule(true);
assertTrue(oneDWriteOptions.getUseXModule() == true);
// All GS1 Databar Stacked
GS1DatabarStackedBarcodeWriteOptions gs1DatabarStackedWriteOptions = (GS1DatabarStackedBarcodeWriteOptions) writer
.getDefaultOptions(BarcodeSymbology.GS1_DATA_BAR_STACKED);
gs1DatabarStackedWriteOptions.setUseXModule(true);
assertTrue(gs1DatabarStackedWriteOptions.getUseXModule() == true);
// Patch Code
PatchCodeBarcodeWriteOptions patchCodeWriteOptions = (PatchCodeBarcodeWriteOptions) writer
.getDefaultOptions(BarcodeSymbology.PATCH_CODE);
patchCodeWriteOptions.setUseXModule(true);
assertTrue(patchCodeWriteOptions.getUseXModule() == true);
// All PostNet/Planet
PostNetPlanetBarcodeWriteOptions postNetPlanetWriteOptions = (PostNetPlanetBarcodeWriteOptions) writer
.getDefaultOptions(BarcodeSymbology.POST_NET);
postNetPlanetWriteOptions.setUseXModule(true);
assertTrue(postNetPlanetWriteOptions.getUseXModule() == true);
// Pharma code
PharmaCodeBarcodeWriteOptions pharmaCodeBarcodeWriteOptions = (PharmaCodeBarcodeWriteOptions) writer
.getDefaultOptions(BarcodeSymbology.PHARMA_CODE);
pharmaCodeBarcodeWriteOptions.setUseXModule(true);
pharmaCodeBarcodeWriteOptions.setXModule(30);
assertTrue(pharmaCodeBarcodeWriteOptions.getUseXModule() == true);
// We will use this object to save files
RasterCodecs codecs = new RasterCodecs();
// Get all the available write symbologies
BarcodeSymbology[] symbologies = writer.getAvailableSymbologies();
assertTrue(symbologies != null);
for (BarcodeSymbology symbology : symbologies) {
assertTrue(symbology != null);
System.out.printf("Processing %s%n", symbology);
// Create the default data for this symbology
BarcodeData data = BarcodeData.createDefaultBarcodeData(symbology);
// Calculate its size with default options
writer.calculateBarcodeDataBounds(LeadRect.getEmpty(), resolution, resolution, data, null);
// Create an image to write the data to
LeadRect pixels = data.getBounds();
RasterImage image = RasterImage.create(pixels.getWidth(), pixels.getHeight(), 1, resolution,
RasterColor.fromKnownColor(RasterKnownColor.WHITE));
// Write the barcode with default options
writer.writeBarcode(image, data, null);
// Save it
String outFileName = combine(outDir, symbology + ".tif");
codecs.save(image, outFileName, RasterImageFormat.TIF, 1);
assertTrue((new File(outFileName)).exists());
}
}
Help Collections
Raster .NET | C API | C++ Class Library | HTML5 JavaScript
Document .NET | C API | C++ Class Library | HTML5 JavaScript
Medical .NET | C API | C++ Class Library | HTML5 JavaScript
Medical Web Viewer .NET
Multimedia
Direct Show .NET | C API | Filters
Media Foundation .NET | C API | Transforms
Supported Platforms
.NET, Java, Android, and iOS/macOS Assemblies
Imaging, Medical, and Document
C API/C++ Class Libraries
Imaging, Medical, and Document
HTML5 JavaScript Libraries
Imaging, Medical, and Document