LDicomPrintSCU::UpdateAnnotationBox

#include "ltdic.h"

L_INT LDicomPrintSCU::UpdateAnnotationBox(pszAnnotationBoxInstanceUID, uAnnotationPosition, pszTextString)

Requests the Print SCP to update the specified Basic Annotation Box SOP Instance.

Parameters

const L_TCHAR * pszAnnotationBoxInstanceUID

Character string that contains the SOP Instance UID of the Annotation Box to be updated. The function will return an error if this is NULL or if an empty string is specified. The function LDicomPrintSCU::GetAnnotationBoxInstanceUID returns the SOP Instance UID of a particular Annotation Box.

L_UINT16 uAnnotationPosition

Specifies the Value of the Attribute Annotation Position (2030,0010).

const L_TCHAR * pszTextString

Character string that contains the Value of the Attribute Text String (2030,0020). If this is set to NULL, the Attribute will not be included in the request to the Print SCP and hence will not be updated.

Returns

Value Meaning
0 The specified Basic Annotation Box SOP Instance was updated successfully.
DICOM_ERROR_PRINTSCU_FAILURE_STATUS The response of the Print SCP specifies a Failure status code.
DICOM_ERROR_PRINTSCU_CLASS_NOT_SUPPORTED The Basic Annotation Box SOP Class is not supported on the Association.
> 0 An error occurred. Refer to Return Codes.

Comments

When the Print SCP is requested to create a Film Box, and if an Annotation Display Format ID is specified, the Print SCP will also create one or more Annotation Boxes, based on the Annotation Display Format ID. This will happen only if the Basic Annotation Box SOP Class is supported on the Association. This function updates a particular Annotation Box. The Annotation Box specified (by the SOP Instance UID) must belong to the current (last created) Film Box.

The function will not return until it receives the response of the Print SCP, or an error occurs. The function LDicomPrintSCU::GetLastOperationStatus can be used to obtain the status code specified in the response of the Print SCP. When the return value of the function UpdateAnnotationBox is 0, then the Annotation Box was updated successfully, with either a Success or Warning status code in the response of the Print SCP.

Required DLLs and Libraries

Platforms

Win32, x64

Help Version 21.0.2021.7.2
Products | Support | Contact Us | Intellectual Property Notices
© 1991-2021 LEAD Technologies, Inc. All Rights Reserved.

LEADTOOLS DICOM C++ Class Library Help
Products | Support | Contact Us | Intellectual Property Notices
© 1991-2021 LEAD Technologies, Inc. All Rights Reserved.