#include "ltivw.h"
L_LTIVW_API L_INT L_DispContainerGetRulerUnit(hCellWnd, puUnit, uFlags)
L_HWND hCellWnd; |
handle to the cell window |
L_UINT * puUnit; |
pointer to a variable |
L_UINT uFlags; |
reserved for future use |
Retrieves the measurement unit used for the viewer ruler.
Parameter | Description | |
hCellWnd | A handle to the window that represents the Medical Viewer Cell. | |
puUnit | Pointer to a variable to be updated with the measurement unit used for the viewer ruler, or any other measurement tool inside the image viewer. Possible values are: | |
Value | Meaning | |
CONTAINER_RULERUNIT_INCHES | [0] Inches. | |
CONTAINER_RULERUNIT_FEET | [1] Feet. | |
CONTAINER_RULERUNIT_MICROMETERS | [2] Micrometers. | |
CONTAINER_RULERUNIT_MILLIMETERS | [3] Millimeters. | |
CONTAINER_RULERUNIT_CENTIMETERS | [4] Centimeters. This is the default value. | |
CONTAINER_RULERUNIT_METERS | [5] Meters. | |
uFlags | Reserved for future use. Pass 0. |
SUCCESS |
The function was successful. |
< 1 |
An error occurred. Refer to Return Codes. |
To change the viewer ruler unit, call the L_DispContainerSetRulerUnit function.
You can show the current measurement unit on the cell by passing the DISPWIN_TYPE_RULERUNIT to the parameter uType when calling the L_DispContainerSetCellTag function.
Required DLLs and Libraries
LTIVW For a listing of the exact DLLs and Libraries needed, based on the toolkit version, refer to Files To Be Included With Your Application. |
For an example, refer to L_DispContainerCalibrateRuler.